Combination Smoke And Carbon Monoxide Detector With Display Smoke CO Alarm Detector

Product Details:
Place of Origin: China
Brand Name: Ariza
Certification: UL217&UL2034 REPORT
Model Number: F-05
Payment & Shipping Terms:
Minimum Order Quantity: 500pcs
Price: 10.15$-11.3$
Packaging Details: Qty 50pcs/carton Size:39.5x34x32.5cm G.W:10kg/carton
Delivery Time: 7-15days
Payment Terms: T/T, Western Union, MoneyGram,Paypal
Supply Ability: 30000pcs/month
Specifications Product Description Request A Quote
Specifications
Specifications
Product Name: Combination Smoke And Carbon Monoxide Detector With Display
Sensor: Electrochemical Carbon Monoxide Sensor And Infrared Photoelectric Sensor
Battery: 3*1.5V AA Battery
Carbon Monoxide Sensor Detect Concentration: 000-999PPM
Smokesensor Sensitive: 0.1%db/m-9.9%db/m
Alarm Indication: LCD Display/Light/sound Prompt
Dimensions: 104*39mm
Battery Capacity: Low Battery Alarm
Certification: UL217&UL2034
Material: ABS
High Light:

UL217 Smoke Alarm Detector

,

UL2034 Smoke Alarm Detector

,

ABS Smoke CO Alarm Detector

Product Description

Combination Smoke And Carbon Monoxide Detector With Display Smoke CO Alarm Detector

 

Combination smoke detector and carbon monoxide detector can detect the threat of these two gases.
carbon monoxide detector alarm using high accurate electrochemical sensor, alerts you to carbon monoxide danger.
photoelectric sensor detects smoke, smoke detector while minimizing false alarms.
smoke co detector operated unit installs quickly and easily without an electrician at home or bedroom.
lcd display concentration ppm, real-time monitoring to protect your safety

 

Sepcification  

Product name Combination Smoke And Carbon Monoxide Detector With Display
Sensor
Electrochemical carbon monoxide sensor and Infrared photoelectric sensor
Battery
3*1.5V AA battery
Carbon monoxide sensor detect concentration
000-999PPM
Temperature
0℃~50℃
Humidity
10-95%
Smokesensor sensitive 0.1%db/m-9.9%db/m
Operation Current <10uA (standby); <70mA (alarm)
Alarm Sensitivity 0.09 - 0.17 dB/m
Certification UL217&UL2034

 

Installation Instructions
 
1. FIRST START
Insert 3 pieces 1.5VAA battery to the detector, the buzzer will make a sound “di",the detector starting preheating,It will display 2 minutes counting when the detector is in starting -up.

2. BUTTON
Press TEST/RESET button,LCD display “0” ppm, LED flickering and the detector will sound continuousalarm .

3. PEAK RECORD
Long press TEST /RESET button for more than 10 seconds, check alarm concentration, pressTEST /RESET button again for clean up.  

 
4. INDICATION LIGHT
Under the normal standby situation, the green light flashes one time at every 68seconds.  
 
5. LOW BATTERY WARNING
When the battery capacity islow, the redlight flashesone time at every 20seconds and the LCD display “Lb".

 
6. ALARM
When the unit detect the carbon monoxide gas concentrations more than 100PPM, it will alarming, and the buzzer will make sound “di” four times at every 5seconds, the redlight flashes, and continue alarm. please immediately turn off the valve,open the windows and doors, then call your emergency service .If there isafire, when the unit detect the smoke concentration over than 0.1%db/m, it will alarming, the blue light flash rapidly and the buzzer continue alarm .

 
7. ALARMPAUSE(Hushmode)
Silence your detector by immediately pressing the test button when non-emergency, causes nuisancealarms. The LED circle flashing to remind you that the detector has been silenced.LED light flash once every 10 seconds that alarm had entered the silentmode(insilentmode, press the button, the buzzeralarm ming, atthesametime, the redlight cycle flashmuteoff). The alarm will automatically reset after 10 minutes.
 
Combination Smoke And Carbon Monoxide Detector With Display Smoke CO Alarm Detector 0
 
Notice
 
1. The detector is easy to be effected by the sharppounding and shock in transit or installation ,leadto not work.
2. This is a carbon monoxide and smoke combodetector, can not detect the combustible gas (such as liquefied petroleum gas,natural gas, methane,etc.
3. Scheduled maintenance: surface cleaning permonth, specialist inspection per half year.
4. Do not use the detergent to clean the detector, this will damage the detector.
5. Do not spray any sprays such as air freshener, hairspray, etc.
6. This product is only used to reduce the accident, can not make sure everytime. Except use ourdetector in right way, please also pay more attention in your daily life and strengthen safety and security conciousness.
 
 
Combination Smoke And Carbon Monoxide Detector With Display Smoke CO Alarm Detector 1
 
FAQ
 

Q: How can i place an order?
Please provide the details of your requirements as clear as possible. So we can send you the offer at the first time.
A: For designing or further discussion, it is better to contact us with Skype / email / phone, in case of any delays.


Q: How about the quality of the personal alarm ?

A: We produce every product with good quality materials and fully test three times before shippment. What is more, our quality

areapproved by CE RoHS SGS & FCC, IOS9001, BSCI.

 

Q: Can i have a sample order?

A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.


Q: What is your terms of delivery?
A: We accept EXW, FOB, CFR, CIF, DDU, DDP, etc. You can choose the one which is the most convenient or cost effective for you.

 

Q: How do you ship the goods and how long does it take arrive?

A: We usually ship by DHL(3-5days), UPS(4-6days), Fedex(4-6days), TNT(4-6days), Air(7-10days), or by sea(25-30days)at your request.